charger28 2.2.1
|
Charger 28 Click example. More...
Macros | |
| #define | MIKROBUS_POSITION_CHARGER28 MIKROBUS_1 |
Functions | |
| void | application_init (void) |
| void | application_task (void) |
| int | main (void) |
Charger 28 Click example.
This example demonstrates the use of the Charger 28 Click board by monitoring various parameters of the charging system, such as input voltage (VBUS), battery voltage (VBAT), system voltage (VSYS), charging current (IBAT), and chip temperature (TDIE). Additionally, it reads and interprets the charger status and fault registers to provide detailed status and error feedback during operation.
The demo application is composed of two sections:
Initializes the driver and performs the default configuration of the Charger 28 Click by disabling charging, resetting registers, disabling the TS pin, configuring the ADC, and re-enabling charging.
Periodically retrieves and logs charging parameters such as input voltage, battery voltage, system voltage, charging current, and temperature. The application also reads the status and fault registers to determine the current charging state and logs the information for debugging or monitoring purposes.
| #define MIKROBUS_POSITION_CHARGER28 MIKROBUS_1 |
| void application_init | ( | void | ) |
< Logger config object.
< Click config object.
Logger initialization. Default baud rate: 115200 Default log level: LOG_LEVEL_DEBUG
| void application_task | ( | void | ) |
| int main | ( | void | ) |